研究用フローサイトと理化学分析

世界のリサーチ分野のお客さまへ先端の検査装置のご案内です。

お問い合わせはこちら

sysmex

研究用フローサイトと理化学分析sysmex

CyFlow CD23 PE-Cy7

品番 CH091551
抗体名 Anti-Hu CD23 PE-CY7,EBVCS-5
包装単位 100 tests
濃度 -
容量 0.4 ml
関連製品
(アイソタイプコントロール)
Mouse IgG1 PE-Cy7 (CF148611)
反応性|交差吸着 Human レーザー Blue, Green, Yellow
抗原 CD23, FcɛRII , BLAST-2 最大蛍光波長 785 nm
クローン EBVCS-5 最大励起波長 496 nm, 565 nm
ホスト Mouse 標識/Format PE-Cy7
アイソタイプ IgG1 研究分野 Immunophenotyping
クローナリティ monoclonal 用途

Flow cytometry

Anti-Hu CD23 PE-CY7,EBVCS-5

特異性

The mouse monoclonal antibody EBVCS-5 recognizes an epitope located in the stalk region of human low affinity IgE receptor (CD23) between the 37 and 25 kDa cleavage sites.

抗原情報

CD23 (Fc ε RII), the low affinity IgE receptor, is a 45 kDa type II membrane glycoprotein expressed more or less on eosinophils, follicular dendritic cells, Langerhans cells, mature B cells (mainly upon activation), EBV-transformed lymphoblasts, monocytes, and subpopulation of platelets. A soluble form of 37 kDa and other its fragments were also described. CD23 mediates IgE-dependent cytotoxicity by eosinophils and macrophages, and downregulates IgE secretion in response to high levels of IgE, involving release of pro-inflammatory cytokines.

利用方法

The reagent is designed for Flow Cytometry analysis of human blood cells. Recommended usage is 4 µl reagent / 100 µl of whole blood or 10^6 cells in a suspension. The content of a vial (0.4 ml) is sufficient for 100 tests.

保存方法

Avoid prolonged exposure to light. Store in the dark at 2-8°C. Do not freeze.

安定性情報

Do not use after expiration date stamped on vial label.

レファレンス

• Belleau JT, Gandhi RK, McPherson HM, Lew DB: Research upregulation of CD23 (FcepsilonRII) expression in human airway smooth muscle cells (huASMC) in response to IL‑4, GM‑CSF, and IL‑4/GM‑CSF. Clin·Mol·Allergy. 2005·May·20; 3:6. <·PMID:·15907205·>
• Byrd JC, O'Brien S, Flinn IW, Kipps TJ, Weiss M, Rai K, Lin TS, Woodworth J, Wynne D, Reid J, Molina A, Leigh B, Harris S: Phase 1 study of lumiliximab with detailed pharmacokinetic and pharmacodynamic measurements in patients with relapsed or refractory chronic lymphocytic leukemia. Clin·Cancer·Res. 2007·Aug·1; 13(15‑1):4448‑55. <·PMID:·17671129·>
• Ling NR, Stevenson FK, Brown B: Urinary excretion of CD23 antigen in normal individuals and patients with chronic lymphocytic leukaemia (CLL). Clin·Exp·Immunol. 1991·Dec; 86(3):360‑6. <·PMID:·1721010·>
• Rumi C, Rutella S, Leone G, Bonini S: Fc‑RII/CD23 receptor on circulating human eosinophils. Blood. 1998·Apr·1; 91(7):2621‑2. <·PMID:·9516167·>
• Yamaoka KA, Arock M, Issaly F, Dugas N, Le Goff L, Kolb JP: Granulocyte macrophage colony stimulating factor induces Fc epsilon RII/CD23 expression on normal human polymorphonuclear neutrophils. Int·Immunol. 1996·Apr; 8(4):479‑90. <·PMID:·8722638·>

Available Safety Data Sheets

CyFlow™ monoclonal antibodies SDS CA EN

Available Technical Data Sheets

CyFlow™ CD23 PE-Cy7 (EBVCS-5) CH091551 TDS (US)